NBS Source
I'm a manufacturer
Compare variants

Aluminium Kalzip Standing Seam - Vertical Cladding System - Standing Seam Cladding

Verified by manufacturer 2 months ago

0.20 W/m²K U-Value System (50/333, 50/429, 50/444)

Kalzip Ltd Variant:
Third party certifications:
  • ISO 14001 Environmental Management Systems

    Certificate type

  • ISO 45001 Health and Safety Management

    Certificate type

  • ISO 9001 Quality Management

    Certificate type

  • EPD

    EPD

    Certificate type

  • European Technical Approval (ETA)

    European Technical Approval (ETA)

    Certificate type

Kalzip standing seam system comprising of aluminium outer skin, E-clips and tophats with lightweight non-combustible insulation, vapour control layer and an inner trapezoidal sheet.

Jump to:
+44 (0)1942 295500 Website

Application

Aluminium Standing Seam system for wall applications.

Description

Kalzip standing seam and metal liner cladding system, with a thermal transmittance (U-value) designed to suit the project requirements.


The Kalzip liner cladding system is ideal where speed of installation on a project is of utmost importance.


Kalzip liners are available as standard in high grade steel or aluminium. Standard finishes include a galvanized, or white enamel finish to suit the internal application. A full range of alternative colours and coatings is also available on request.


All work undertaken should be fully in accordance with Kalzip standard recommendations and by Kalzip approved contractors.

Kalzip sheets to be installed as per cladding manufacturer's instructions.


Features and benefits:

  • The Kalzip liner cladding system has the outer Kalzip standing seam sheet and the internal Kalzip liner trapezoidal profiled liner sheet laid in the same direction.
  • Suitable for a wide range of applications.


For detailed information on load/ span capability, U-values and acoustic variations of the Kalzip liner cladding system please contact the Kalzip Technical Team.

General information

Color

Bronze

Gold

Copper

Other

Guidance for specification option:

Available in natural and pre-weathered aluminium, zinc, various bronze and gold patinas, copper, stainless steel and coated to any RAL or BS colour. Refer to product literature for details.

Manufacturer guidance

Various colour options available refer to product literature.

Finish

Galvanized

Textured

Anti-graffiti

Anodized

Coated

Show more

Manufacturer guidance

Various finish options available refer to product literature.

Material

Aluminium

Copper

Stainless steel

Zinc

Steel

Show more

Shape

Other

Guidance for specification option:

Flexible form and shape.

Length

Bespoke

Width

Bespoke

Height

Bespoke

Warranty description

Other

Guidance for specification option:

Various warranty periods are available, consult manufacturer.


15 year

20 year

25 year

30 year

Show more

Uniclass

Ss_25_20_68_50 Metal profiled sheet self-supporting cladding systemsPrimary

CAWS

H31/10 Metal

H31/120 Metal

Product range

Standing Seam

Specification data - Metal profiled sheet self-supporting cladding systems

Liner sheets

-

Material

Kalzip Trapezoidal liner sheet in galvanised steel to BS EN 10326. 0.7 mm (Nominal) with Enamel White coating.

Guidance for specification option:

For internal use.

Kalzip Trapezoidal liner sheet in aluminium 0.9 mm Stucco Embossed.

Manufacturer guidance

See also Bearing width below.

Primary fasteners

5.5 mm diameter carbon steel self-drilling fasteners (SD-3-T15-5.5x25).

End and side laps

Side laps to be stitched at maximum 400 mm centres with 4.8 mm diameter carbon steel self-drilling stitching fasteners (SL2-T-4.8x20).

Air and vapour control layer

-

Material

Kalzip VCL Clear - Reinforced virgin polyethylene with 530 MNs/g vapour resistivity.

Guidance for specification option:

Continuity:

  • Lay as work proceeds ensuring continuity. Lap side and end laps of vapour control layer and seal with sealant tape achieving full bond. Seal with sealant tape to perimeter and to pipes, ducts, structural members etc. which abut or pass through achieving a full bond.

Repairs:

  • Carefully check for tears and punctures and seal them with lapped patch of same vapour control layer material and seal with sealing tape along all edges achieving full bond.

Sealing

Seal with one row of sealant tape, not less than 50 mm.

Spacers

Support clips, steel reinforced polyamide Kalzip E-clips type E160 fixed to 30 mm deep steel tophats channels.

Thermal insulation

Kalzip Plus40 Insulation, 205 mm.

Guidance for specification option:

Manufactured with ECOSE™ technology. Finalized insulation thickness dependant on support clip frequency - subject to calculation by Kalzip.

Firestops

To accurately match sheet profile. Adhesive recommended by profile filler manufacturer.

External sheets

-

Material

Kalzip Standing Seam 50/333.

Kalzip Standing Seam 50/429.

Kalzip Standing Seam 50/444.

Manufacturer guidance

Specify Finish separately below.

Primary fasteners

6 mm diameter stainless steel torque controlled fasteners (SDK3-S-377-6.0x45).
Position and frequency to be determined by calculation by Kalzip Technical.

Secondary fixings

Steel tophats to be secured to steel saddles at purlin positions.
Position and frequency to be determined by calculation by Kalzip Technical.

End and side laps

Sheets to be supplied in continuous lengths and mechanically seamed to support clips with Kalzip zipping machine.

System accessories

Extruded aluminium alloy (EN AW-6061) gable end hooks.
Extruded aluminium alloy (EN AW-6063) drip angle 40 x 20 mm.
Extruded aluminium alloy (EN AW-6063) flat bar 22 x 6 mm.
Extruded aluminium alloy (EN AW-6063) gable end channel.
Extruded aluminium alloy (EN AW-6063) tolerance gable clip extrusion.
Fabricated aluminium alloy (EN AW-3004) flashings.
Fabricated aluminium alloy (EN AW-3004) ridge closures (KZ 65/400).
Fabricated welded soaker units.
Kalzip profile eaves fillers.
Kalzip profile ridge fillers.

Guidance for specification option:

Fabricated aluminium alloy (EN AW-3004) flashings and Fabricated welded soaker units:

  • Material and finish as per cladding sheets or as per project requirements - consult manufacturer for details.

Thermal transmittance (U-Value)

0.20 W/m²K.

Bearing width

58 mm (minimum).

Type

Kalzip profiled fillers - Closed cell cross-linked polyethylene with a minimum density of 30 kg/m³.

Thickness

Guidance for specification option:

30 mm minimum.

Locate where shown on drawings and wherever necessary to close off corrugation cavities from the outside and inside of the building. Ensuring a tight fit, leaving no gaps.

Finish

Aluminium, AluPlusPatina.

Aluminium, natural stucco embossed.

Aluminium, with a PVDF paint coating.

Aluminium, with an HPC paint coating.

AluPlusZinc.

Show more

Manufacturer guidance

External sheets finish only.

Shape

Guidance for specification option:

Insert requirements to suit project requirements.

Dimensions

Guidance for specification option:

Insert requirements to suit project requirements.

Third-party certification

Institute fur Bautechnic Zulassungbescheid N R 14.1-181.

Movement joints

Leave space between sheets to coincide with structural movement joints. Fix weathertight movement joint cover to sheets on one side only. Movement joint cover detail to be as per Kalzip Ltd recommended detail KZ-0-MISC-K-8-006.

Fixing method

Fixing sheets generally:
Remove all drilling swarf, dust, debris and any other foreign matter before finally fixing sheets into position. Protect sheets adequately during fixing and up to practical completion against mechanical damage, corrosion and disfigurement. Rectify any defects as quickly as practicable to minimise damage and nuisance. Install fasteners to correct tightness using any special tools recommended by the manufacturer.

Installation

Kalzip sheets to be installed by mechanically seaming sheets to support clips with Kalzip zipping machine.
Kalzip sheets to be installed as per cladding manufacturer's instructions, British Board of Agrément Certification No. 98/3481 and Institute fur Bautechnic Zulassungbescheid N R 14.1-181.

Material

Cappings, closure pieces, flashings, trims, fillers, spacers, tapes, sealants, fixings, etc, where not specified, to be types recommended by the cladding manufacturer.

Fasteners

Type(s), size(s), material(s) and finish(es) as specified, or in the absence of such specification, as recommended for the purpose by the cladding manufacturer.

Material

Soffits, where not specified, to be recommended by the cladding manufacturer.

Support

Frequency of soffit supports determined by project engineer.

Sustainability data

Contains Red List materials

No

Country of material origin

Germany

Country of product manufacture

United Kingdom

Material

Aluminium

Copper

Stainless steel

Zinc

Steel

Show more

Manufacturing plant location

Embodied carbon

A1-A3 (production stage) as defined in BS EN 15804

9.61 kg CO₂ eq/kg

Manufacturer guidance

Refer to EPD certificate.

Recyclability

Excellent

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

100 %

Guidance for specification option:

 Recycled aluminium top sheet.

Expected Life

40 year

Third party certifications

Third party certifications

ISO 14001 Environmental Management Systems

ISO 14001 Environmental Management Systems

Kalzip ISO 14001

ISO 45001 Health and Safety Management

ISO 45001 Health and Safety Management

Kalzip ISO 45001

ISO 9001 Quality Management

ISO 9001 Quality Management

Kalzip ISO 9001

EPD

EPD

Kalzip Standing Seam EPD

European Technical Approval (ETA)

European Technical Approval (ETA)

Kalzip ETA

Literature

Kalzip case studies

Kalzip case studies

Kalzip systems

Kalzip systems

Kalzip Finishes and Colours

Kalzip Finishes and Colours