Verified by manufacturer 3 months ago
Fire-Spec Lintels
Pre-stressed lintels ensuring optimum performance with enhanced fire resistance and a smooth, consistent colour finish.
For use in 215 mm wide walls and partitions where 60 minutes fire resistance is required. Designed to be used in fair faced, paint grade and blockwork situations.
Faced Fire-Spec Lintels have a class C fair faced finish and are available with 60, 90 or 120 minutes fire rating, dependent upon the section width. Other concrete sections can be made with a fire resistance equal to or greater than our standard range and our technical team with their special knowledge of concrete can advise you on which sections would achieve a specific fire resistance and strength rating and offer a design solution should this not be detailed in our load span tables.
Features and benefits:
Color | Grey |
Finish | Smooth Guidance for specification option: Smooth, consistent colour finish. |
Material | Concrete |
Shape | Rectangle |
Length | 600 mm 900 mm 1200 mm 1500 mm 1800 mm |
Width | 215 mm |
Height | 290 mm |
Warranty description | 50 year Guidance for specification option: Design life. |
Uniclass | |
CAWS | F30/745 Prestressed concrete lintels |
Product range |
Standard | To BS EN 845-2. |
Types | Single. |
Dimensions | |
Length | 600 mm.900 mm.1200 mm.1500 mm.1800 mm.2100 mm.2400 mm.2700 mm.3000 mm.3300 mm.3600 mm.Guidance for specification option: Longer lengths available on request - up to 4800 mm. |
Cross section | 215 x 290 mm. |
Characteristics | |
Deflection under load | 1.68 mm.Guidance for specification option: Deflection at 1/3 of load capacity. |
Freeze/ thaw | Resistant. |
Mass | 150 k.g./m. |
Resistance to fire | Deflection at 1/3 of load capacity. |
Thermal conductivity | 1.52 W/m.K.Guidance for specification option: Thermal conductivity λ 10,dry, mat, to EN 1745. |
Water absorption | 1.15 Cw.s. |
Surface finish | Class C fair faced. |
Contains Red List materials | No |
Country of material origin | United Kingdom |
Country of product manufacture | United Kingdom |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | 0.19 kg CO₂ eq/kg Self declared Guidance for specification option: Raw materials are locally and responsibly sourced. |
Recyclability | Manufacturer guidanceAt the end of life, concrete can be recycled. Crushed concrete can be used as aggregates in new concrete or as sub-base and fill. |
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
- | 6 | |
- | 5 |
Economy Lintels
Faced Fire R11 [60 minutes] - Lintels
Faced Fire R13 [60 minutes] - Lintels
Faced Fire R190 [60 minutes] - Lintels
Faced Fire R2 [60 minutes] - Lintels
Faced Fire R3 [60 minutes] - Lintels
Faced Fire R7 [60 minutes] - Lintels
Faced Fire R8 [60 minutes] - Lintels
Faced Fire S5 [60 minutes] - Lintels
Faced Fire S8 [60 minutes] - Lintels