A bonafide non-combustible air and vapour permeable breather membrane suitable for enclosed masonry clad facades or for use as a base layer in a rainscreen façade applied directly to the backing wall.
ME055 is suitable for:
ME055 is typically over sheathing boards or other substrates with a reaction to fire of at least Class A2-s1,d0. The overlapping seams and perimeter edges are sealed with illbruck ME356 FR Sealing Tape. In addition, illbruck SP025 Fire Membrane Adhesive may also be used to provide an enhanced air and water-tight connection to adjacent walls and floor junctions.
illbruck ME055 FR Breather Membrane is a monolithic glass fibre-reinforced breather membrane that achieves a Class A1 Reaction to Fire according to BS EN 13501-1. ME055 is highly suited to applications in buildings that have been classified as "Relevant Buildings" as defined in Approved Document B, April 2019. Often used in conjunction with other illbruck slit-to-width interface sealing membranes at window and door openings or other linear joints to provide fully compatible and integrated building protection wrap around the external backing wall in a framed and sheathed construction.
Features and benefits:
Color | White |
Finish | Matt Textured |
Material | Glass Fibre |
Shape | Formless Rectangle |
Length | 50000 mm |
Width | 1500 mm |
Height | Manufacturer guidanceMembrane thickness. |
Warranty description | Other Guidance for specification option: Any product which has been applied (a) in accordance with Tremco CPG UK Ltd written instructions and (b) in any applications recommended by Tremco CPG UK Ltd, but which is proved to be defective, will be replaced free of charge. |
Uniclass | |
CAWS | P10/65 Breather membrane P10/320 Breather membrane H92/785 Breather membrane |
Standard | To BS EN 13859-2. |
Performance criteria | |
Water vapour properties | Water vapour resistance to BS EN ISO 12572; 0.15 MN. s/g. |
Fire performance | Reaction to fire: To BS EN 13501-1, Class A1. |
Tensile properties | Tensile strength to BS EN 12311-1, 3500 N/50 mm, ± 400 (longitudinal); 1800 N/50 mm, ± 400 (transverse). |
Class (minimum) | W2.Guidance for specification option: Tested in accordance with BS EN 13111. Manufacturer guidanceResistance to water penetration to BS EN 13859-2. |
Material | Glass fibre fabric. |
Thickness (minimum) | 0.18 mm. |
Reflective face | Non-reflective. |
Execution | Manufacturer guidanceillbruck ME055 A1 Breather Membrane (White), W2 is unfurled and applied directly from the log to the substrates. The membrane is secured with tape to the structure and overlapping seams to create a homogenous and continuous protection layer. Applications should start from the bottom of the building and work upwards overlapping subsequent horizontal and vertical layers by a minimum of 100 mm. Perimeters and overlapping seams are sealed with illbruck ME355 FR Sealing & Joining Tape A2 or other tape specified by illbruck. Some details e.g. floor junction or solid walls may require the use of illbruck SP025 Fire Membrane Adhesive in addition to the illbruck ME355 FR Sealing & Joining Tape A2. |
Colour | Dull white, non reflective. |
Elongation at break (to BS EN 12311-1) | 5%, ± 2 (longitudinal); 4%, ± 2 (transverse). |
Tear resistance (to BS EN 12310-1) | 350 N, ± 50 (longitudinal); 420 N, ± 50 (transverse). |
Air permeability | To EN 13859 (Test Method EN 12114), 27.0 m³/(hr x m² x 50 Pa). |
Water vapour diffusion resistance | To EN 12572, 177. |
Water vapour permeability | To EN 12572, 177. Manufacturer guidanceWater Vapour Permeability (µ). |
Water vapour permeability in SD | To EN 12572, 0.03 m. |
UV resistance | 3 months without cladding. |
Application temperature | +5°C to +40°C. |
Service temperature | -36°C to +150°C. |
Country of material origin | France |