NBS Source
I'm a manufacturer

Description

One layer of Gyproc ThermaLine PIR 38mm to one side of Gypframe 146 I 80 ā€˜Iā€™ Stud framework forming an independent lining to masonry background. For heights up to 6900mm.

General information

Finish

-

Manufacturer guidance

The system should be finished using either one of our Thistle or ThistlePro plasters, or Gyproc jointing products. See the product range guides on the British Gypsum website for more information.

Material

Gypsum

Metal

Plasterboard

Steel

Height

6900 mm

Uniclass

Ss_25_25_45_35 Gypsum board wall lining systemsPrimary

CAWS

K10/155 Wall lining system (metal studs)

K10/30 Metal stud

Product range

Wall linings / GypLyner Independent

Specification data - Gypsum board wall lining systems

Support

Base channel: Gypframe 148 DC 60 Deep Flange Floor & Ceiling Channel.
Head channel: Gypframe 148 DC 60 Deep Flange Floor & Ceiling Channel.
Stud: Gypframe 146 I 80 'I' Stud.
Abutments and openings: Gypframe 146 S 50 'C' Stud.

Linings

Board side 1, Layer 1: Gyproc ThermaLine PIR 38mm.

Fasteners

Screws side 1, Layer 1: British Gypsum Jack-Point Screws 60mm.

Joint treatment

Fixing strap: Gypframe GFS1 Fixing Strap.
Fixing T: Gypframe GFT1 Fixing 'T'.

Finish

The system should be finished using either one of our Thistle or ThistlePro plasters, or Gyproc jointing products. See the product range guides on the British Gypsum website for more information.

System accessories

Sealant: Gyproc Sealant.
Thermal sealant: Gyproc Sealant.

Execution

Please review details on the British Gypsum website at: https://www.british-gypsum.com/Specification/White-Book-Specification-Selector/wall-linings/GypLyner-Independent/GIWL-146-I-80-PIR-B-EN#details

Strength grade

Not Stated

Partition height

6900mm

Background

Background: Masonry