Verified by manufacturer 28 days ago
Popout - hydraulic rooflight
Weathertightness Testing
Certificate type
Vertical rising rooflight with corner actuators.
Rooflights and ventilation.
Vertical rising rooflight with corner actuators.
Features and benefits:
Color | Clear Guidance for specification option: Glass. Other Guidance for specification option: Framing. |
Material | Glass Aluminium Fiber-glass Steel Stainless steel |
Shape | Rectangle Square |
Length | Bespoke |
Width | Bespoke |
Uniclass | |
CAWS | L10/45 Rooflights L10/460 Rooflights |
Form | Popout rooflight (vertical rising) with corner actuators (hydraulic). |
Size | Guidance for specification option: Consult manufacturer for options and insert requirements. |
Product performance | |
Whole window U-value | To BS EN 10077, <1.4 W/m²K. |
Frame | |
Material | Aluminium.Manufacturer guidanceThermally broken aluminium profile with fully cleated corners. Reinforced with stainless steel flats as required. Fully welded stainless-steel angles thermally isolated with GRP profiles. |
Finish | |
Coating | Powder coating. |
Colour | Guidance for specification option: Insert requirements; powder coated in any standard RAL colour. |
Film thickness (minimum) | Manufacturer's standard. |
Glazing or infill | |
Type | Toughened safety glass.Heat-strengthened laminate safety glass.Other.Guidance for specification option: Consult manufacturer for alternatives and insert requirements. Options include low iron glass, along with acoustic or security interlayers. See Glazing or infill - Coating below for further options. |
Construction | Double glazed.Manufacturer guidanceConsult manufacturer for further details. Glass thickness is application-dependent. |
Colour | Clear. |
Coating | Low-E to achieve minimum centre pane U-value of 1.1 W/m²K.Guidance for specification option: Standard. Solar control. |
Operation | |
Type | Powered, hydraulic.Guidance for specification option: 24 V actuators concealed within the internal finishes. |
Control | By dead-man operation.Connected to the building management system (BMS).Guidance for specification option: When connecting to a BMS (like Lutron) all sensors should be connected directly to BMS. External control through rain, wind and light sensors.External control through biometric device.External control through remote-control handset.Manufacturer guidanceSee also Power supply for UPS option. |
Power supply | Standard. Uninterrupted power supply (UPS). Guidance for specification option: Achieved by installing a battery backup to allow for operation even during power outage. |
Ironmongery | All fittings in aluminium, stainless steel (304), printed from ABS material or other non-corrosive material. Guidance for specification option: Consult manufacturer for details as required. |
Air permeability | To BS EN 12207, Class 4 at 600 Pa. |
Resistance to wind load | To BS EN 12210, Class E2400. |
Watertightness | To BS EN 12208, Class 9A. |
Performance characteristics | CWCT classification (TN92): Class 2 (if four-edge supported and panels <4.5 m²). |
Contains Red List materials | No |
Country of material origin | Poland |
Country of product manufacture | Poland |
Material | Glass Aluminium Fiber-glass Steel Stainless steel |
Manufacturing plant location | |
Expected Life | 25 year |