Verified by manufacturer 2 days ago
Standing seam roof on open gap boarding (cold, vented)
QA Certificate
Certificate type
EPD
Certificate type
EPD
Certificate type
EPD
Certificate type
EPD
Certificate type
Vented cold roof systems for buildings with humidity classes between 1 and 4 using VMZINC on an open gap softwood boarding (compatible) substrate.
Suitable for buildings in 1 to 4 humidity classes (dwellings with high occupancy, sport halls, etc) with pitches from 3° to the vertical (as well as soffits).
Vented cold roof systems for buildings with humidity classes between 1 and 4 using VMZINC on an open gap softwood boarding (compatible) substrate.
Standing Seam Roof on open gap boarding (cold, vented):
Features and benefits:
System build-up:
____________________________________________________________________________
Standing Seam Roof on plywood (cold, vented):
Features and benefits:
System build-up:
VMZINC PLUS:
A product which allows zinc to be installed on ventilated plywood as well as specific warm (non-ventilated) substrates. The product consists of VMZINC (in all finishes) having a 60 µm coating applied to the underside thus allowing a more varied amount of substrates to be used and eliminating the risk of the formation of white rust on the underside of the zinc standing seam panels. VMZINC PLUS resists to an abrasion of 140 L when tested in accordance with ASTM D 968.
____________________________________________________________________________
Life Cycle Analysis (LCA):
VMZINC undertakes Life Cycle Analysis (LCA) tests on its products and publishes Environmental Product Declarations (EPDs), such as BRE Environmental Profiles. These provide users with comprehensive, reliable and transparent information on relevant environmental characteristics. The information is also used by VMZINC as the basis for its eco-design approach.
Color | Blue Green Grey Red Brown |
Finish | Natural Pre-treated |
Material | Zinc |
Shape | Rectangle Other |
Length | 13000 mm Guidance for specification option: Maximum panel length. Bespoke Guidance for specification option: Overall system. |
Width | 430 mm Guidance for specification option: Panel centres. 530 mm Guidance for specification option: Panel centres. 600 mm Guidance for specification option: Panel centres. Bespoke Guidance for specification option: Overall system. |
Height | 25 mm Guidance for specification option: Standing seam. |
Warranty description | 50 year Guidance for specification option: Up to 50 year material warranty available on a project basis. |
Uniclass | |
CAWS | H74/5 Zinc sheet fully supported covering to dormers H74/150 Zinc sheet fully supported covering to dormers H74/110 Zinc sheet fully supported roof covering |
Product range |
Classification data | |
System performance | Structural performance – wind actions Design of zinc sheet fully supported roof covering systems Durability Aesthetic performance Fire performance |
System manufacturer | VMZINC UK. |
Sarking or roof boarding | 18 mm open gap softwood boards. Guidance for specification option: With 50 mm minimum vented cavity, 10 mm open air inlet at the eave and 10 mm open air outlet at the ridge. 50 mm cavity created with a batten. |
Membrane | VMZINC Membrane. Guidance for specification option: Placed over insulation, VMZINC applied directly over open gap softwood boards. |
Insulation | As required. |
Air and vapour control layer | Guidance for specification option: A VCL is recommended and should be installed on the warm side of the insulation. Insert requirements or omit. |
Carrier | Batten (rafters can be metal or timber). |
Substrate | Not applicable. |
Sheet underlay | |
Fasteners | Screws as required. |
Zinc | Zinc-titanium-copper (VMZINC®), 0.7 mm thick. Guidance for specification option: Standard thickness. Zinc-titanium-copper (VMZINC®), 0.8 mm thick. Guidance for specification option: Suitable for long panels or exposed sites, consult manufacturer for details. |
Longitudinal joints | |
Form | Standing seam joints. |
Fixing standing seam joints | VMZINC clips, 1.4301 (304) stainless steel. The thickness of the fixing clip is 0.5 mm. The sliding clips have a moving component, which is 0.4 mm thick, and a 70 mm long slot. |
Fasteners to substrate | It is recommended that screws be used to secure the clips with three being used per sliding clip. The use of nails offers significantly less resistance, but in the event of using nails, contractors are advised to use ring shank nails. |
Cross joints | |
Form | Double lock welts. Roof steps. |
Eave details | |
Form | Dog tooth. Swept eave on 'T' plate with water check. |
Fixings | Fixed with cleats using a 6 mm rebate on the substrate. |
Verge details | |
Form | Standing seam verge. |
Fixing | |
Top edge | VMZINC stainless steel sliding clip. |
Bottom edge | The eave should be fixed to a 'T' plate with water check which must be secured using cleats. |
Ridge and hip details | |
Form | G3 ridge. Traditional with upstand. |
Fixings | Ridge clip G3. |
Colour | Natural VMZINC®, natural finish. Guidance for specification option: Natural VMZINC® has a shiny metallic appearance when new and develops a patina over time. In facade applications, it may take ten years for the matt grey patina to form. Standard PIGMENTO® BLUE. Guidance for specification option:
Standard PIGMENTO® GREEN. Guidance for specification option:
Standard PIGMENTO® BROWN. Guidance for specification option:
Standard PIGMENTO® RED. Guidance for specification option:
Standard PIGMENTO® GREY. Guidance for specification option:
PIGMENTO® STORM GREY. Guidance for specification option:
PIGMENTO® CHARCOAL GREY. Guidance for specification option:
QUARTZ-ZINC®. Guidance for specification option:
ANTHRA-ZINC®. Guidance for specification option:
AZENGAR®. Guidance for specification option: Pre-weathered finish. Engraved zinc giving a product with a matt, heterogeneous and light aspect. Can be used in the same fashion as other VMZINC® products for both roofs and facades. |
Panel length | Guidance for specification option: Insert requirements, maximum length 13 m. Manufacturer guidanceNote that longer panels may be recommended to be formed in narrower widths, consult manufacturer for details. |
Panel width | 430 mm. 530 mm. 600 mm. Guidance for specification option: Not AZENGAR. |
Custom design | Not required. Required. Guidance for specification option: Consult manufacturer for options and insert requirements. Options include perforated, curved and stamped panels. |
Standard | To EN 15804, ISO 14001 and ISO 9001. |
Panel weight | 6 kg/m² (approximately). |
Reaction to fire | Fire classification according to EN 13501-1:2002: A1 (Natural Zinc/ QUARTZ ZINC/ ANTHRA-ZINC/ AZENGAR); A2-s1,d0 (PIGMENTO and VMZINC). |
Slope | Minimum 3%. |
Contains Red List materials | No |
Country of material origin | France |
Country of product manufacture | France |
Material | Zinc |
Recyclability | 100% Guidance for specification option: Fully recyclable. |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 20 % Guidance for specification option: 20% (approximately). |
Expected Life | 100 year |
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
![]() | IFC2X3 | 1 |
![]() | Revit 2016 | 2 |
VMZINC Standing Seam Installation Guide - Information about the Use and Detailing of VMZINC May 2022
VMZINC Roofing + Rainwater Design Specification & Installation Guidelines Dec 20
VMZINC General Technical Recommendations - Design Guidance for Architects & Contractors.
VMZINC EN15804 Natural Rolled Zinc
ISO 9001
ISO 14001
EN15804 Pre-Weathered QUARTZ PLUS & ANTHRA PLUS
BRE Certification EN15804 Pre-Weathered Rolled QUARTZ & ANTHRA
BRE Certification EN15804 Pre-Weathered PIGMENTO & STRAT
VMZINC Standing Seam Roofing - Standing Seam Roof On Metal Faced Panels (Warm, Non-vented)
VMZINC Standing Seam Roofing - Standing Seam Roof On Plywood (Cold, Vented)
VMZINC Standing Seam Roofing - Standing Seam Roof On Plywood Bonded To Phenolic Foam (Warm, Non-vented)
VMZINC Standing Seam Roofing - Structural Roof (Warm, Non-vented)
VMZINC Standing Seam Warm Roofing - Non-Vented Warm Roof System