NBS Source
I'm a manufacturer

X5 Rooflight

Verified by manufacturer 1 month ago

VELUX Commercial

Uninsulated, aluminium framed kerb with choice of glazing types.

Jump to:
+44 (0) 1592 778916 Website

Application

Flat roof 0–15°.

Description

Features and benefits:

  • Wide range of bespoke sizes from 600x600mm to 1800x2400mm.

Operation and ventilation options include;

  • Fixed
  • Access hatch
  • 140 degree opening AOV (1500mm maximum span/opening width)
  • Electrically operated hinged and vertical lift natural vent
  • Kerb venting, Hinged Vent, Manual, Hit and Miss Vent.
  • Mechanical Ventilation with Fan Unit


Glazing options (Developed U-Values shown) include;

Polycarbonate:

  • Double Skin Polycarbonate 2.7 W/m²K/ Overall 3.6 W/m²K
  • Single Skin Polycarbonate 5.3 W/m²K/ Overall 5.4 W/m²K

Insulated Solid Lid

  • Insulated Solid Lid (single skin aluminium with 16mm structured polycarbonate) 2.2 W/m²K/ Overall 3.3 W/m²K


Various fixing/foot types depending on application available as splayed or vertical include;

  • Type A Foot – to suit flat board insulation
  • Type B Foot – To suit laid to falls
  • Type C Foot - Direct to deck – no insulation
  • Type D - Adaptor kerb – Fixing to a builders kerb or upstand
  • Type E Foot - Fixing to new timber ground
  • Type F – Sleeve Over existing kerb 
  • Type G - for fixing to an existing kerb or plinth

General information

Color

White

Other

Guidance for specification option:

(RAL colours, available on request).

Finish

Powder-coated

Guidance for specification option:

(PPC)

Material

Aluminium

Polycarbonate

Shape

Square

Rectangle

Circle

Warranty description

Guidance for specification option:

Available on request

Uniclass

Pr_30_59_72_31 Framed rooflightsPrimary

CAWS

L10/45 Rooflights

L10/460 Rooflights

Specification data - Framed rooflights

Form

Circular (CIR).

Guidance for specification option:

Polycarbonate only.

Dome (DM).

Guidance for specification option:

Polycarbonate only.

Flat glass (GL).

Pyramid (PY).

Guidance for specification option:

Polycarbonate only.

Size

Up to 1200 x 2400 mm.

Guidance for specification option:

Consult manufacturer for options and insert requirements. Please note that available size will depend upon other specification choices made, including ventilation and application.

Product performance

-

Fire performance

-

Fire resistance

To BS 476, Part 7: Class 1, AA.

Reaction to fire

EN 13501-1: Class B-s1,d0.

Guidance for specification option:

Surface spread of flame: EN 13501-5 + A1: Broof (t4).

Whole window U-value

4 W/m²K.

Frame

-

Material

Aluminium.

Finish

-

Coating

Polyester powder-coating.

Colour

White.

RAL.

Guidance for specification option:

Consult manufacturer and insert requirements.

Film thickness (minimum)

0.6 µm.

Glazing or infill

-

Type

Polycarbonate.

Guidance for specification option:

Not available with Flat glass (GL).

Glass.

Guidance for specification option:

Flat glass (GL) only.

Construction

Single skin (Code 01).

Guidance for specification option:

Not available with Flat glass (GL).

Double skin (Code 02).

Guidance for specification option:

Not available with Flat glass (GL).

Single layer.

Guidance for specification option:

Glass only.

Colour

Bronze.

Guidance for specification option:

Reduces light transmission and solar gain.

Clear.

Guidance for specification option:

Offers high light transmission and allows full vision of views or objects.

Diffused.

Guidance for specification option:

Offers high light transmission and prevents vision of views and objects.

Opal.

Guidance for specification option:

Prevents vision of views and objects.

Coating

Manufacturer's standard.

Integral kerb

Aluminium.

Guidance for specification option:

Consult manufacturer for details.

Operation

-

Type

Hit and Miss vent.

Linear motor vent.

Permanent vent.

Controlled Louvre vent.

Control

Manual.

Electric, 230 V.

Guidance for specification option:

Consult manufacturer for details.

Accessories

Intruder grid – Code IG

Guidance for specification option:

3 mm diameter, fully welded, steel mesh in a 75 mm grid, which is fixed between the upstand and the roof structure. The grid will resist entry even when the rooflight has been compromised or removed.

None.

Execution

Installation of framed rooflights.

Sustainability data

Country of product manufacture

United Kingdom

Material

Aluminium

Polycarbonate

Embodied carbon

A1-A3 (production stage) as defined in BS EN 15804

kg CO₂ eq/m²

Self declared

Guidance for specification option:

Meets BRE EN 15804:2012+A1:2012